The
Adobe
Acrobat Reader is needed to view the forms on this page.
Click here to download the
reader for free.
For information, contact Andy Varian at
avarian@cityofripon.org
or by phone at (209) 599-2108
Edition: April 16, 2007
City of Ripon
Standard Specifications and Standard
Details (61 pages, 170k)
STANDARD DRAWINGS
|
Appendix B MENU
|
G-1, G2, G3 - General Notes (148k)
G-4 Subdivision Design Standards (78k)
G-5 Improvement Plan Standards (78k)
G-6 Pipe Materials (31k)
G-7 Large Diameter Sewer and Storm Drain Pipe (56k)
G-8, G-9, G10 Drafting Standards (97k)
G-11 Signature Blocks (37k)
ST-1, ST-2, ST-3 - Street Design Standards (3 pages, 177k)
ST-4 Conditions for All Weather Roads (55k)
ST-5 Trip Generation Factors (41k)
ST-6 Structural Pavement Design Chart (68k)
ST-7 Street Section Chart and Street Design Standards (57k)
ST-8 Street Design Standards (44k)
ST-8a Concrete Paver Standards (27k)
ST-9 140' Major Arterial Street Section (29k)
ST-10 102' and 50' Street Sections (32k)
ST-10a 82' Street Section (27k)
ST-11 74' and 60' Street Sections (37k)
ST-12 Alternate Cul-De-Sac Detail (52k)
ST-13 Standard Cul-De-Sac Detail (57k)
ST-13a Extended Standard Cul-De-Sac Detail (56k)
ST-13b Cul-De-Sac Island Detail (38k)
ST-14 Special Residential Parking (35k)
ST-15 Special Residential Parking (35k)
ST-16 Special Residential Parking (37k)
ST-17 Alignment for 90° Plus Street Intersections (28k)
ST-18 School Area Pavement Legends (42k)
ST-19 Crosswalk / Stop Bar Placement (28k)
ST-20 Concrete Curb, Gutter & Sidewalk Standards (44k)
ST-21 6" Vertical Curb, Gutter, Sidewalk (37k)
ST-21a 4 1/2 " Drive-Over Curb, Gutter and Sidewalk (45k)
ST-21b Type "C", "D", and "E" Curb and Gutter (51k)
ST-21c Class 2 Bicycle Path and Gutter Pan (40k)
ST-22 Location of Weakened Plane Joints (27k)
ST-23 Standard Residential Driveway with Vertical Curb and Detached Sidewalk (55k)
ST-23a Vertical Curb and Attached Sidewalk (31k)
ST-24 140' Major Arterial Commercial Driveway with Detached Sidewalk (52k)
ST-24a 102' Minor Arterial Commercial Driveway with Detached Sidewalk (50k)
ST-24b 82' and 74' Street ROW Commercial Driveway with Detached Sidewalk (42k)
ST-24c Type 1 Commercial Driveway with Attached Sidewalk (42k)
ST-24d Type 2 Commercial Driveway with Attached Sidewalk (40k)
ST-26 Typical Wheelchair Ramp at Intersections (46k)
ST-26a Residential Wheelchair Ramp Detail for Detached Sidewalk (39k)
ST-26b Residential Wheelchair Ramp Detail for Detached Sidewalk to Attached Sidewalk (38k)
ST-27 Typical Wheelchair Ramp Detail for Commercial/Industrial Applications (46k)
ST-27a Commercial/Industrial Wheelchair Ramp Detail for 140' Right-of-Way (34k)
ST-27b Commercial/Industrial Wheelchair Ramp Detail for 102' Right-of-Way (33k)
ST-27c Commercial/Industrial Wheelchair Ramp Detail for 82' and 74' Right-of-Way (33k)
ST-28 Typical Mid Block Wheelchair Ramp Detail with Detached Sidewalk (28k)
ST-28a Typical Mid Block Wheelchair Ramp Detail with Attached Sidewalk (26k)
ST-29 Wheelchair Ramp Groove and Lip Detail (28k)
ST-30 Raised Paver Intersection Plan View Detail (112k)
ST-30a Raised Paver Intersection Section View Detail (79k)
ST-31 140' Right-of-Way Roundabout Geometrics (55k)
ST-32 102' Right-of-Way Roundabout Geometrics (54k)
ST-33 84' Right-of-Way Roundabout Geometrics (44k)
W-1, W-2 Water\W1-W2_GenRequirements.pdf (85k)
W-3 Water Line Design Criteria (72k)
W-4, W-5, W-6 Water\W4-W6_CriteriaforSeparation.pdf (213k)
W-7 Criteria for Separation of Water Mains from Sanitary Sewer and Storm Drains - Case 1 (60k)
W-7a Criteria for Separation of Water Mains from Sanitary Sewer and Storm Drains - Case 2 (60k)
W-8 Water Design Data (64k)
W-9 Tracer Wire Installation Detail (42k)
W-10 Fire Lane Details (82K)
W-10a Fire Lane Notes (50k)
W-11 Valve Box Details (50k)
W-12 Thrust Box Details (56k)
W-13 1 1/2" and 2" Metered Water Service Installation (66k)
W-14 1" Metered Water Service Installation (57k)
W-15 Remote Meter Read Installation (44k)
W-16 Permanent and Temporary Blowoff Details (46k)
W-17 Blank
W-18 Blank
W-19 Reduced Pressure Principle Backflow Prevention Assembly for 1" to 1 1/2" (47k)
W-20 Reduced Pressure Principle Backflow Prevention Assembly 3" and Larger (51k)
W-21 Fire Hydrant Spacing (44k)
W-22 Fire Hydrant at Back of Curb in Parkway Planter (41k)
W-22a Fire Hydrant Notes (54k)
W-23 Fire Hydrant with Vertical Curb and Attached Sidewalk (42k)
W-23a Fire Hydrant with Drive-Over Curb and Attached Sidewalk (44k)
W-24 Fire Sprinkler Connection Located More than 30 Feet from Nearest Fire Hydrant (58k)
W-25 Fire Sprinkler Connection Located Within 30 Feet from Nearest Fire Hydrant (56k)
W-26 Water Sampling Station Detail (52k)
W-27 Typical Offset Unit (41k)
W-28 Air and Vacuum Release Valve Detail (65k)
W-29 Waterline Hot Tap Detail (37k)
STORM DRAIN
SD-1, SD-2 Criteria for Design of Storm Drain Facilities (104k)
SD-3, a,b,c Rainfall Intensity Curves (267k)
SD-4 Inlet Time (73k)
SD-5 Storm Drain Design Sheet (72k)
SD-6 Storm Drain Data (38k)
SD-7 Frame and Grate, Type 2 Curb Inlet Catch Basin (54k)
SD-7a Type 2 Curb Inlet Catch Basin (47k)
SD-8 Frame and Grate, Type 1 Curb Inlet Catch Basin (56k)
SD-8a 24" Round Curb Inlet Catch Basin Detail (54k)
SD-8b 24" Square Curb Inlet Catch Basin Detail (52k)
SD-9 Parking Lot Catch Basin (50k)
SD-10 Type 1 Standard Storm Manhole (56k)
SD-10a Storm Drain Plug (26k)
SD-11 Separation Manhole Detail (56k)
SD-12, SD-13 Type 2 Manhole for Pipe 36" Diameter and Larger (122k)
SD-14 Typical Sand and Oil Trap (43k)
SD-15 Storm Drain Manhole Frame and Cover (59k)
S-1 Criteria for Design of Sanitary Sewer Facilities (93k)
S-2 Sanitary Sewer Design Data (71k)
S-3 Lift Station Design Data (27k)
S-4 Sanitary Sewer Design Sheet (41k)
S-5 Sanitary Sewer Data (75k)
S-6 Sanitary Sewer Manhole (54k)
S-7 Sanitary Sewer Drip Manhole (Exterior Piping) (47K)
S-8 Sanitary Sewer Manhole Frame and Cover (56k)
S-9 Lamphole and Lamphole Ring and Cover Detail (50k)
S-10 Cleanout Riser (59k)
S-11 House Lateral Detail (96k)
S-12 Typical Grease Trap (49k)
S-13 Sewer Stack House Lateral (33k)
U-1 Typical Location of Underground Utilities (54k)
U-2 Blank
U-3 Typical Deep Trench Backfill (46k)
U-4 Jack and Boring (50k)
U-5 Concrete Saddle Detail (44k)
U-6 Existing Street Trench Section (75k)
U-7 Existing Street Trench Section for Pipe "4" and Smaller (70k)
U-8 Pot Hole / Bore Pit (Existing Street) Additional Pavement Restoration (32k)
U-9 Location of Underground Utilities (52k)
L-1, L-2 Street and Parking Lot Lighting(2 pages, 113k)
L-3 Street and Parking Lot Lighting Pole and Base Standards (44k)
L-3a Street Light Pole Base Placement (68k)
L-4 Locations of 100 and 150 Watt Lights (51k)
L-5 Locations of 200 Watt Lights (42k)
IRR-1, IRR-2, IRR-3 Typical Tree Well Irrigation System Requirements (3 pages, 345k)
IRR-4 Typical Tree Well Installation (101k)
IRR-5 Tree Well Detail (108k)
M-1 Survey Monument Marker (21k)
M-2 Special Monument Installation (48k)
M-3 Survey Monument (52k)
M-4 Typical Interior Lot Grading Detail (61k)
M-5 Blank
M-6 Adjusting Street Facilities to Grade (28k)
M-7 Street Name Sign (42k)
M-8 Street Name Sign Location (32k)
M-9 Land Reduction Transition (37k)
M-10 Barricades for Terminating Streets (40k)
M-11 Sound Wall Design Criteria (61k)
M-12 Sound Walls (42k)
M-13 Property Line Retaining Wall (30k)
M-14 Chain Link Fence Standards (75k)
M-15, M-16 Off Street Parking Standards (131k)
M-17 Blank
M-18 10' x 12' Concrete Block Refuse Container Enclosure (51k)
M-19 Typical Expansion Joint and Valley Gutter (34k)
M-20 Gate Rollers Detail (32k)
GENERAL STORM WATER POLLUTION PREVENTION NOTES (SWPP)
SWPP-1 General Storm Water Pollution Prevention Notes (55k)
SWPP-2 Storm Drain Inlet Protection (32k)
SWPP-3 Storm Drain Marker (36k)
SWPP-4a On Grade Temporary Washout Facility (36k)
SWPP-4b Below Grade Temporary Concrete Washout Facility (33k)
SWPP-5 Stabilized Construction Entrance (44k)
SWPP-6 Field Inlet/Manhole Protection (61k)